3.1.6 Troubleshooting Tips
If Dynamic C is unable to establish communication with the RabbitLink, make sure
that the RabbitLink is powered on, and make sure that the Ethernet cable is firmly con-
nected to the RabbitLink and that the LED labeled LINK is on.
If Dynamic C is still unable to establish communication with the RabbitLink, make
sure that Dynamic C has the correct IP address and control port information. Look in
the
Communications dialog box.
If Dynamic C is able to establish communication with the RabbitLink, but midway
through the download process displays either "Error receiving Flash ID from target"or
"Target Communication Error,” check to make sure that the program download cable is
plugged in correctly from the RabbitLink to the controller being programmed, and that
the controller is powered on.