RabbitLink EG2110 Manual do Utilizador Página 18

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 58
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 17
14 RabbitLink (EG2110)
3. Configure the RabbitLink network parameters. This is done using the serial console
commands. Typing the command “show” results in a listing of the current network
addresses.
Please refer to Appendix E, “Serial Console Commands,” for a description of all the
commands. If a DHCP server was not used, the following serial console commands are
required:
set ip x.x.x.x // factory default is 10.10.1.100
set gateway x.x.x.x // factory default is 10.10.1.1
set netmask x.x.x.x // factory default is 255.255.255.0
An alternative for setting the required network addresses is to change the default values
in the RabbitLink firmware, download.c.
Vista de página 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 57 58

Comentários a estes Manuais

Sem comentários